15
Connect up to four sensor devices to the terminals that are numbered 1 to 8 at
the back panel. Each pair of terminals is for the ground (-) and positive (+) input
voltage. For instance:
Terminal 1 : Connect to the ground (-) wire of Sensor 1
Terminal 2 : Connect to the positive (+) wire of Sensor 1
....
....
Terminal 7 : Connect to the ground (-) wire of Sensor 4
Terminal 8 : Connect to the positive (+) wire of Sensor 4
Connect an alarm device to the terminals that are numbered 9 and 10:
Terminal 9 : Connect to the positive (+) wire of the alarm device
Terminal 10 : Connect to the ground (-) wire of the alarm device
Desktop/Laptop computer
Connect EB1104 NET DVR and PC with the USB cable in the package before
you execute the playback application.